EX9000/EX9000-Modbus Series
     
   
 
 
EX9260-MTCP          7 isolated DI & 4 relay DO with ModbusTCP daisy chain module
 

Special Features:

 

2-ports(RJ-45) Ethernet 10/100 Based-T Comm.
Daisy chain connection with auto-bypass protection
Support Modbus/TCP,TCP/IP,UDP,ICMP,ARP
Support Automatic DIO Sync.(peer-to-peer).
DO Auto-Off Time Mode.
Support 4 Relay output,0.6A@125VAC/2A@30VDC, RL0,RL1,RL2 Form C and RL3 Form A.
Support 7 Isolated single ended with Dry/Wet Contact(common source or ground)
Fully Photo-Isolation 3750Vrms
Protocol: ASCII Format & Modbus TCP

  

Specifications/ 
   
Interface:
Communication 2-port(RJ45) Ethernet 10/100 Based-T comm, Daisy chain connection with auto-bypass protection.
Protocol Modbus/TCP, TCP/IP, UDP, ICMP and ARP
Led indication Led for power and Ethernet link status
Isolation Digital Input:
Input channels 7 (DI0~6)
Input type: Dry contact: single ended with common source.
     ● logic level 0 (active): Close to DI.GND
     ● logic level 1 (inactive) : open
Wet contact: single ended with common source/ground.
     ● logic level 0 (active) : +5V to +30VDC max
     ● logic level 1 (inactive): +2VDC max
Logic level status can be inversed via ASCII/Modbus command
Counter Input 300Hz counter input (32-bit+1-bit overflow)
Optical Isolation Voltage 3750Vrms
Relay Output:
Output channels 4 (RL0,RL1,RL2 Form C(SPDT) and RL3 Form A(SPST NO)
Relay type: Surge strength: 500V
Relay contact rating: 0.6A/125Vac, 2A/30Vdc
Operate Time: 3mS max.
Release Time: 2mS max.
Min Life: 5*105 ops
Pulse output Each channel supports 300Hz pulse output
Optical Isolation Voltage 3750Vrms
Power requirement:
Consumption 2.5W (Typical)
Power input 10~30VDC
Operating temperature: -10 ~ 70° C (14 ~ 158° F)
Operating temperature: -25 ~ 85 °C (13 ~ 185 °F)
Humidity 5~95% RH, non-condensing


 

Features:


 

 

 

Automatic DIO Synchronization (peer-to peer)
EX9200-MTCP series module also provide a Automatic DIO Synchronization function. With peer-to-peer networking, users can define the mapping between a Pair of EX9200-MTCP series modules so that input values will be directly transferred to output channels. A single digital output channel(Local/ Remote device) is activated(1/0 or toggle)dependent on the digital input channels state data pattern. When the specified DI channels state data pattern changed from “Match” to “Not match” the corresponding DO well be set to active(1 or 0).

 

 